Vastral, Ahmedabad, Gujarat
GST No. 24AAJCP7915M1ZX
Call 08048971769 90% Response Rate
Product Brochure
Mounting Options | Side Mount, Bottom Mount |
Media Type | Dry Material |
Packaging Type | Box |
Brand | FILSA |
Enclosure | IP65 according DIN EN60529 |
Model | AD INOX |
Maximum Pressure | +0.5 bar |
Maximum Voltage | 250 V AC |
Product Temperature | -20 to +200 Deg C |
Ambient Temperature | -20 to +80 Deg C |
Weight | 1.85 kg |
Housing Materials | Aluminium, RAL 7001 coated |
Intended use:
Membrane level indicator with Stainless Steel membrane to be used to control normally the minimum level of bulk solids in silos or vessels.
These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy flow and a bulk density from 0.3 to 2.5 t/m3.
Function:
The membrane must to be exposed to the material.The movement of the switch is the result of the pressure exerted by the incoming bulk material against the membrane which forces the membrane to move backwards, reversing the position of the switch and the signal is used for example to control the transport system in the silo.
The models "A-100", "AD", "SR" y "CD2M" and the models with S.S. membrane have a regulation system by a spring that allows the adjustment of the sensitivity. Tightening the regulation nut to reduce the sensitivity and increase the strain of the material to activate the microswitch. Clockwise insensitive.
The models are adjusted at their maximum sensitivity. It is necessary to ensure the proper pressure to the membrane that returns the membrane when there is no product covering it.
Mechanical connection:
Drill holes in the silo or vessel and mount the indicator using screws, rods, fasteners or nuts M6 making sure of the easy flow of the material and ensure that the product leaves the membrane without product on it.
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | LFV 12 |
Usage/Application | Industrial, Liquid level measurement |
Brand | Trumen |
Process Temperature | -20 to 80 DegreeC (-4 to 176 DegreeF) |
Material | Stainless Steel |
Media Type | Liquid |
Max. Viscosity | 10,000cP. (= cPose/(g/cm3)) (Higher viscosity available on request) |
Ambient Temperature | -20 to 70 DegreeC (-4 to 158 DegreeF) |
Extended Process Temperature | -30 to 150 DegreeC (-22 to 302 DegreeF) (extensions & heat sinks required) |
Process Pressure | Absolute / max. 15 bar |
Wetted Parts | SS 316 or SS 316L |
Enclosure Protection Class | IP-65/67 as per IS-13947 |
Enclosure Material | SS316 |
Electronics of LFV12 excites the piezo-electric-crystals inside the tuning fork, which makes the fork tines vibrate at their natural resonance frequency in free air.
When the fork tines are immersed in liquid, the frequency of fork vibration falls due to the density of liquid.
This change in frequency is detected by electronic circuit.
Liquid presence is thus detected.
View Complete details
Product Brochure
Model Name/Number | LFV |
Brand | Trumen |
Process Temperature | -20 to 80 DegreeC (-4 to 176 DegreeF) |
Max. Viscosity | 10,000 cStokes (= cPose/(g/cm3)) (Higher viscosity available on request) |
Ambient Temperature | -20 to 60 DegreeC (-4 to 140 DegreeF) |
Extended Process Temperature | -30 to 200 DegreeC (-22 to 392 DegreeF) (extensions & heat sinks required) |
Process Pressure | Absolute / max. 15 bar |
Wetted Parts | SS 316 or SS 316L,PTFE,PFA,TEFZEL,HALAR |
Extensions Tube | SS 304,SS 316,SS 316L |
Length | 50 to 3000 mm |
View Complete details
Product Brochure
Model Name/Number | LSV |
Brand | Trumen |
Material/Body | SS |
Process Temperature | -20 to 80 DegreeC (-4 to 176 DegreeF) |
Ambient Temperature | -20 to 70 DegreeC (-4 to 158 DegreeF) |
Extended Process Temperature | -30 to 200 DegreeC (-22 to 392 DegreeF) {250 DegreeC available on request} |
Length | 125 to 3000 mm |
Wetted Parts | SS 316 or SS 316L |
View Complete details
Product Brochure
Model Name/Number | LSR |
Operating Temperature | -20 to 80 DegreeC (-4 to 176 DegreeF) |
Brand | Trumen |
Ambient Process Temperature | -30 to 100 DegreeC (-22 to 212 DegreeF) (extensions & heat sinks required) |
Pressure | Atmospheric |
Blade Material | SS 316 or SS 316L |
Max Length | 100 to 1000 mm |
Blade Thickness | 2 mm |
Application:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Media Type | Liquid |
Brand | Trumen |
Mounting Options | Top Mount |
Material | Stainless Steel |
Pole And Throw Specification | SPST |
Model Name/Number | MLS20 |
Float Diameter | 30,52,60 mm |
Switch Type | Reed Switch (SPST/SPDT) |
Process Connection | Flange / Thread |
Maximum Pressure | Up to 20 Kg/cm2 |
Mac. Temperature | Up to 150 Degree C, others on request |
Min. Specific Gravity | 0.8 |
Guided Stem | Dia 16 mm |
No. of Floats | Single/ Multiple (Max.4) |
Wetted Part | SS/MS/PP/PTFE/PVDF |
View Complete details
Product Brochure
Process Temperature | -20 Degree C- 80 Degree C (-4 Degree F-176 Degree F) |
Model Name/Number | LFV-11 |
Brand | Trumen |
Supply | 12 to 60 VDC |
Process Temperature Max | 150 Degree C |
Process Pressure Max | 15 Bar |
Output Limit | 250mA max. Short Circuit Safe. |
Max. Viscosity | 10,000 cStokes (= cPose/(g/cm3)) (Higher viscosity available on request) |
Ambient Temperature | -20 Degree C- 70 Degree C (-4 Degree F-158 Degree F) |
Wetted Parts | SS 316 or SS 316L |
Enclosure Material | SS316 |
Enclosure Protection Class | P-65/67 as per IS-13947 |
Vibration Test | As per IEC 60068 part 2-6 sinusoidal,10-55Hz,0.15mm |
Sensor Insertion Length | LFV12 : 50 mm excluding threads,LFV11 : 128 mm including threads |
Electronics of LFV12 excites the piezo-electric-crystals inside the tuning fork, which makes the fork tines vibrate at their natural resonance frequency in free air.
When the fork tines are immersed in liquid, the frequency of fork vibration falls due to the density of liquid.
This change in frequency is detected by electronic circuit.
Liquid presence is thus detected.
View Complete details
Product Brochure
Model Name/Number | CD |
Brand | Filsa |
Maximum Pressure | +0.5 bar |
Maximum Voltage | 250 V AC |
CD Standard Ambient Temperature | -20 to +60 Deg C |
CD with Aluminium Housing Ambient temperature | -25 to +80 Deg C |
Protection | IP53 / IP40 depending on the position of the cable gland |
CD Standard Weight | 0.48 kg |
CD with Aluminium Housing Weight | 0.95 kg |
Housing Materials | Glass reinforced Polyester (Under request Aluminium) |
Versatile membrane level indicator. Is to be used to control the maximum or minimum level of bulk solids in silos or vessels. These controllers consist of a switch actuated by a membrane and it is recommended for dusty and powdery, granulated and grainy bulk goods like dust, flour, grain, sand, plastic, etc. with an easy flow and a bulk density from 0.3 to 2.5 t/m3.
The membrane must to be exposed to the material. The movement of the switch is the result of the pressure exerted by the incoming bulk material against the membrane which forces the membrane to move backwards, reversing the position of the switch and the signal is used for example to control the transport system in the silo.
The models “A-100”, “AD”, “SR” y “CD2M” and the models with S.S. membrane have a regulation system by a spring that allows the adjustment of the sensitivity. Tightening the regulation nut to reduce the sensitivity and increase the strain of the material to activate the microswitch. Clockwise insensitive.
The models are adjusted at their maximum sensitivity. It is necessary to ensure the proper pressure to the membrane that returns the membrane when there is no product covering it.
Drill holes in the silo or vessel and mount the indicator using screws, rods, fasteners or nuts M6 making sure of the easy flow of the material and ensure that the product leaves the membrane without product on it.
View Complete details
Product Brochure
Model Number | LMC |
Brand | Trumen |
Process Temperature | -20 to 100 DegreeC (-4 to 212 DegreeF) |
Min. Dielectric Constant | 1.6 (non-hygroscopic) |
Ambient Temperature | -20 to 70 DegreeC (-4 to 158 DegreeF) |
PTFE Insulation Extended Process Temperature | -30 to 250 DegreeC (-22 to 482 DegreeF) |
Ceramic Insulation Extended Process Temperature | -30 to 600 DegreeC (-22 to 1,112 DegreeF) (extensions & heat sinks required) |
Process Pressure | Absolute / max. 15 bar |
Wetted Parts | SS-304, SS-316, SS-316L, PTFE, part ceramic |
Additional Information:
View Complete details
Product Brochure
Process Temperature | -20 to 100 DegreeC (-4 to 212 DegreeF) |
Brand | Trumen |
Ambient Temperature | -20 to 60 DegreeC (-4 to 140 DegreeF) |
Extended Process Temperature PTFE Insulation | -30 to 250 DegreeC (-22 to 482 DegreeF) |
Extended Process Temperature Ceramic Insulation | -30 to 600 DegreeC (-22 to 1,112 DegreeF) (extensions & heat sinks required) |
Wetted Parts | SS-304, SS 316, SS-316L, PTFE, part ceramic |
Rigid Rod Probe Insertion Length | 50 to 3000 mm |
Flexible Rope Probe Insertion Length | 100 to 20000 mm |
Model Name | LSY |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Mounting Options | Top Mount, Side Mount |
Model Name/Number | LSVR |
Material | Stainless Steel |
Usage/Application | Industrial |
Brand | Trumen |
Switch Type | 1 DPDT potential free relay contact output |
Current Rating | 5 A each @ 24VDC or 220VAC |
Pole And Throw Specification | DPDT |
Media Type | Dry Material |
Min. Density | More Than 350 gram/litre,not fluidized |
Ambient Temperature | -20 to 70 DegreeC (-4 to 158 DegreeF) |
Process Temperature | -20 to 80 DegreeC (-4 to 176 DegreeF) |
Extended Process Temperature | -30 to 250 DegreeC (-22 to 482 DegreeF) (extensions & heat sinks required) |
Process Pressure | Absolute / max. 15 bar |
Mountings | NPT / BSP 1",11/4",11/2",2" etc Flanged : ANSI/JIS/DIN/ASA/custom |
Extensions Tube | SS 304,SS 316,SS 316L |
Power Consumption | 0.5 VA max. |
Length | 250 to 3000 mm |
Vibrating rod is a single element tunned mechanical element-type level sensing device.
Electronics of LSV-R excites the piezo-electric-crystals inside the tuning rod, which makes the rod vibrate at it’s natural resonance frequency in free air.
When Material touches the rod, vibration stops as resonance gets disturbed.
Amplitudes of vibration are above threshold when rod is free to vibrate.
Amplitudes of vibration, as sensed by the electronics falls below the threshold, Materials presence is thus detected by observing the amplitude of vibration.
View Complete details
Product Brochure
Model Name/Number | LWS |
Brand | Trumen |
Process Temperature | -20 to 100 DegreeC (-4 to 212 DegreeF) |
Min Conductivity | 20 uSiemens |
Ambient Temperature | -20 to 60 DegreeC (-4 to 140 DegreeF) |
Extended Process Temperature | -30 to 200 DegreeC (-22 to 392 DegreeF) (extensions & heat sinks required) |
Process Pressure | Absolute / max. 5 bar |
Wetted Parts | SS-304, SS-316, SS-316L, PTFE, part ceramic |
Probe Length | Flush installtion to 3,000 mm for rod probe and upto 20,000 mm for rope probe |