Vastral, Ahmedabad, Gujarat
GST No. 24AAJCP7915M1ZX
Call 08048971769 64% Response Rate
Send Enquiry
Minimum Order Quantity: 01 Piece
Product Brochure
| Pressure Range | 0-100 bar |
| Usage/Application | Air,non-combustible and non-aggressive gases application |
| Output Type | Analog: 4 ... 20 mA or 0 ... 10 V,3-wire |
| Accuracy | +-0.5% FS,min. +-1 Pa |
| Working And Storage Temperature | -20 to +70 DegreeC |
| Brand | Beck GmbH |
| Model Name/Number | 984 Series |
| Supply voltage (AC / DC) | 24 V |
| Maximum Working Pressure | 0-50 kPa |
| Protection Type | IP54 |
| Rated Supply Voltage | 18...30 VAC / VDC |
| Response Time | 0.2 s and 1 s (standard) |
| Supply voltage | 18-30 Vac/Vdc (For 984M) |
The differential pressure transmitters of the 984 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch.
For an optimum adaptation to the application, the transmitter can be switched between various pressure ranges. The factory setting is the most sensitive range. For the series 984M and 984A the less sensitive second range will be selected by simply removing a jumper. For the series 984Q the available eight ranges can be selected by a rotary selector switch.
Applications: Monitoring of gaseous, non-combustible and non-aggressive media. Possible usage areas are:
Additional Information:
View Complete details
Minimum Order Quantity: 60 Piece
Product Brochure
| Pressure Range | 0-100 bar |
| Accuracy | +-0.5% FS, min. +-1 Pa |
| Brand | Beck GmbH |
| Model Name/Number | 982R |
| Supply voltage (AC / DC) | 24 V |
| Protection Type | IP54 with protection cover |
| Storage Temperature and Moisture | -20 to 70 DegreeC |
| Process Wetted Material | ABS |
| Response Time | Standard 1.0 s and 0.2 s |
| Supply Voltage For 2 Wire Version | 18-30 VDC |
| Output Signal For 3 Wire Version | 0-10 V or 4-20 mA |
| Output Signal For 2 Wire Version | 4-20 mA |
| Working And Storage Temperature | -20 to 70 Degree C |
| Supply Voltage For 3 Wire Version | 18-30 VAC / VDC |
The differential pressure transmitters of the 982R series are used to measure differential pressure, overpressure and vacuum. They provide one adjustable pressure range and one output signal. Monitoring of gaseous, non-combustible and non-aggressive media.
The end of the pressure range can be reduced to 50% of its factory set full scale value simply by the use of a push-button.
Applications:
Features:
Additional Information:
View Complete details
Product Brochure
| Dial Size | 1.5 inch / 40 mm |
| Display Type | Digital |
| Measuring Range | 0 to 1000 mmWC |
| Usage/Application | Measure differential pressure, overpressure and vacuum |
| Brand | Beck GmbH |
| Use | Vacuum |
| Model Name/Number | 990 |
| Storage Temperature | -10 to + 70 Degree C |
| Working Temperature | 0 to + 50 Degree C |
| Process Connection | 4 mm and 6 mm - SS hose connections |
| Supply Voltage | 18 to 30 VAC / VDC |
| Output Signal | 0-10 V or 4-20 mA |
| Electrical Connection | Screw terminals for wires and strands up to 1.5mm2 |
| Protection Class | IP20 |
Additional Information:
View Complete details
Product Brochure
| Pressure Range | +-100, 100, 250, 500, 1000, 1500, 2000, 2500 Pa |
| Operating Range | +-100, 100, 250, 500, 1000, 1500, 2000, 2500 Pa |
| Output Signal | 4-20 mA |
| Measurement Type | Differential Pressure |
| Accuracy | 1% |
| Supply voltage (AC / DC) | 24 V |
| Process Wetted Material | SS316 |
| Operating temperature: | -20 +50 DegreeC (with autozero calibration -5 +50 DegreeC) -40 +50 DegreeC (-40C model) |
| Power consumption: | 1.0 W 1.2 W with output current 20 mA |
| Supply voltage: | 24 VDC +-10 % / 24 VAC +-10 % |
| Response time: | 0.8 / 8 s |
| Protection standard: | IP54 |
Field adjustable, multi-range differential pressure transmitters for air
DPT-R8 series differential pressure transmitters are engineered for building automation in the HVAC/R industry. The most technologically advanced transmitters on the market measuring static and differential pressure, with field selectable units, range and output, all in a single device.
DPT-R8 series devices include:
• Multiple measurement units, field selectable via jumper, including: inWC, mmWC, Pa, mbar.
• 8 field selectable measurement ranges, unidirectional or bi-directional, selectable via jumper.
• Proportional output options including: voltage (0–10 V) and current (4–20 mA).
View Complete details
Product Brochure
| Pressure Range | 0-100 bar |
| Working And Storage Temperature | 20... +70 DegreeC |
| Brand | Beck GmbH |
| Supply voltage (AC / DC) | 24 V |
| Rated Supply Voltage | 18...30 VDC |
| Product Weight | approx. 120 gr |
| Response Time | 0.2 s and 1 s |
| Housing dimensions | approx. 85 x 58 mm |
| Protection class | IP54 with protection cap or IP00 without protection cap |
| Process connection | Hose connection with 6 mm outer diameter |
The differential pressure transmitters of the 984 series are used to measure differential pressure, overpressure and vacuum. They provide up to 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch.
For an optimum adaptation to the application, the transmitter can be switched between various pressure ranges. The factory setting is the most sensitive range. For the series 984M and 984A the less sensitive second range will be selected by simply removing a jumper. For the series 984Q the available eight ranges can be selected by a rotary selector switch.
View Complete details
Product Brochure
| Pressure Range | 0-100 bar |
| Output Type | 4to20 mA |
| Accuracy | +-1% FS, min. +-1 Pa |
| Model Name/Number | 985-MODBUS |
| Working And Storage Temperature | -20 ... 70 DegreeC |
| Brand | Beck GmbH |
| Supply voltage (AC / DC) | 24 V |
| Product Weight | approx. 140 gr |
| Supply Voltage Limits | 30 VAC / VDC |
Communication:
The digital signal Modbus enables direct connection to control / regulating systems.
Configuration of volume flow or flow velocity measurement:
1. Select a calculation formula and enter a k-factor. Both dependents on the type of ventilator or measuring probe.
2. Or create a reference volume flow or flow velocity, which is entered directly.
The modbus is used to set the device. Please read the exact procedure in the manual.
Adjustable response time:
The response time of the output signal can be variably set via Modbus.
Easy offset calibration:
For 985M-Modbus and 985VM-Modbus press the MODE/Offset button or set via Modbus in an unpressurized state to adjust the offset to zero. The Versions 985A-Modbus and 985VA-Modbus perform an automated zero offset compensation.
Display:
A red LED display shows the pressure value, volume flow or flow velocity.
Mounting position:
Can be mounted in any position. The zero offset calibration eliminates any possible position error.
View Complete details
Product Brochure
| Pressure Range | 0-10 bar |
| Usage/Application | Measurement technology in the sanitary and industrial sector |
| Working And Storage Temperature | -20 to +85 DegreeC |
| Brand | Beck GmbH |
| Model Name/Number | Differential Pressure Transmitter 988 |
| Supply voltage (AC / DC) | 24 V |
| Maximum Working Pressure | 0-10 bar |
| Rated Supply Voltage | 24 VDC |
| Process Wetted Material | pressure chamber Brass / Stainless steel |
| Product Weight | ca. 450 g |
| Response Time | 4 ms / 2 ms |
| Humidity | 0 -95% rH (not-condensed) |
Pressure range
For an optimal adaptation to the application, different pressure ranges are available. The measurement is carried out by a ceramic pressure measuring cell, temperature-compensated via internal PTC.
Output signal
In the 3-wire version there is an output signal of 0 … 10 V, or 4 … 20 mA available. For the 2-wire version the transmitter provides an output signal of 4 … 20 mA.
Electrical connection
The electrical connection of the transmitter is optionally available with a 4-pin standardized device plug according to DIN EN 175301 Form A, or with a 4-pin M12 flange plug, A-coded, according to DIN EN 61079.
OEM versions, assembled versions and different connection threads, as well as other measuring ranges are available on request.
View Complete details
Product Brochure
| Pressure Range | 0-100 bar |
| Usage/Application | Building automation and air conditioning systems |
| Working And Storage Temperature | -20 to +70 DegreeC |
| Brand | Beck GmbH |
| Model Name/Number | Transmitter 985-Modbus |
| Overload pressure max | 0 to 10 bar |
| Voltage | 30 VAC |
| Supply voltage (AC / DC) | 24 V |
| Storage Temperature and Moisture | 20 ... 70 DegreeC 10 ... 50 DegreeC |
| Process Wetted Material | ABS |
Communication:
The digital signal Modbus enables direct connection to control / regulating systems.
Configuration of volume flow or flow velocity measurement:
1. Select a calculation formula and enter a k-factor. Both dependents on the type of ventilator or measuring probe.
2. Or create a reference volume flow or flow velocity, which is entered directly.
The modbus is used to set the device. Please read the exact procedure in the manual.
Adjustable response time:
The response time of the output signal can be variably set via Modbus.
Easy offset calibration:
For 985M-Modbus and 985VM-Modbus press the MODE/Offset button or set via Modbus in an unpressurized state to adjust the offset to zero. The Versions 985A-Modbus and 985VA-Modbus perform an automated zero offset compensation.
Display:
A red LED display shows the pressure value, volume flow or flow velocity.
Mounting position:
Can be mounted in any position. The zero offset calibration eliminates any possible position error.
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
| Pressure Range | ±500 Pa |
| Operating Range | -100 ... 100 / -250 ... 250 / -300 ... 300 / -500 ... 500 Pascal |
| Output Type | Analog: 0 ... 10 V |
| Output Signal | 4-20 mA |
| Model Name/Number | DPI |
| Brand | HK Instruments Oy |
| Accuracy | +-1.5 % FS |
| Measurement Type | Differential Pressure |
| Supply Voltage | 24 V |
| Rated Supply Voltage | 24 VAC or VDC,+-10 % |
| Response Time | 0.5 ...10 sec |
| Protection Standard | IP54 |
| Storage Temperature | -20 to 70 Deg C |
The DPI series electronic pressure measuring devices are engineered for building automation in HVAC/R industry. The most technologically advanced and versatile electronic differential pressure switches on the market, combining up to two relay outputs and 0-10 V output options.
The DPI includes the following field selectable features:
Additional Information:
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
| Pressure Range | 0-100 bar |
| Usage/Application | Air and non-combustible and non-aggressive gases applications |
| Accuracy | +-0.5% FS, min. +-1 Pa |
| Model Name/Number | 985 Seres |
| Brand | Beck GmbH |
| Supply voltage (AC / DC) | 24 V |
| Protection Type | IP65 |
| Storage Temperature and Moisture | -20 to +70 DegreeC |
| Response Time | 0.2 s and 1 s (standard) |
| Supply Voltage | 18-30 VAC / VDC |
| Working And Storage Temperature | -20 To + 70 Degree C |
Additional Information:
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
| Pressure Range | 0-500 bar |
| Output Signal | 4-20 mA |
| Output Type | Analogue |
| Usage/Application | air, all non-aggressive gases application |
| Measurement Type | Differential Pressure |
| Accuracy | +-0.2% FS or +-0.5% FS |
| Working And Storage Temperature | - 10 .. 70 Degree C |
| Model Name/Number | P26 |
| Brand | Halstrup-Walcher GmbH |
| Supply voltage (AC / DC) | 24 V |
| Process Wetted Material | SS316 |
| Response Time | 25 ms |
| Analog Output | 4-20 mA and 0-10 V |
| Operating Temperature | 10 to 50 Degree C |
| Protection Class | IP65 (Weatherproof) |
| Max. Measurement Range | 0-100 kPa (Bidirectional also) |
| Cable Glands | 3 x M16 |
| Min. Measurement Range | 0-10 Pascal (Bidirectional also) other upon customer request |
| Medium | Air,All non-aggressive gases |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Pressure Range | 0-500 bar |
| Usage/Application | air, all non-aggressive gases application |
| Output Signal | 4-20 mA |
| Accuracy | +-0.2% FS or +-0.5% FS |
| Model Name/Number | P34 |
| Working And Storage Temperature | - 10 to 70 Degree C |
| Brand | Halstrup-Walcher GmbH |
| Measurement Type | Differential Pressure |
| Supply voltage (AC / DC) | 24 V |
| Process Wetted Material | SS316 |
| Temperature Coefficient Span | 0.03 % of FS / K (10 to 50 Degree C) |
| Max. Measurement Range | 0 to 100 KPA |
| Sensor Response Time | 25 ms |
| Power Supply | 24 VAC / DC +- 10 % |
| Protection Class | IP 20 |
| Time Constants | 25 ms - 60 s (adjustable) |
| Min. Measurement Range | 0 to 10 PA |
| Operating Temperature | 10 to 50 Degree C |
Special features:
Additional Information:
View Complete details
Product Brochure
| Pressure Range | 0-500 bar |
| Output Signal | 4-20 mA |
| Usage/Application | air, all non-aggressive and non-flammable gases application |
| Measurement Type | Differential Pressure |
| Accuracy | +- 1% of the set value |
| Working And Storage Temperature | - 10 to 70 Degree C with display: - 5 to 55 Degree C |
| Brand | Halstrup-Walcher GmbH |
| Model Name/Number | PS17 |
| Supply voltage (AC / DC) | 24 V |
| Process Wetted Material | SS316 |
| Response Time | 25 ms |
| Air Humidity | 0 - 80 % RH |
| Protection Class | IP67 |
| Temperature Coefficient Span | 0.1% of max. value/K |
| Calibration Temperature | 22 Degree C |
Special features:
Additional Information:
View Complete details
Product Brochure
| Type | Strain Gauge |
| Suitable Media | Air |
| Output Type | Analogue (0-10 V or 4 to 20 mA) |
| Usage/Application | air, all non-aggressive gases applications |
| Brand | Halstrup-Walcher GmbH |
| Model Name/Number | PU/PI |
| Accuracy | +- 0.5% or +- 1% FS |
| Rated Supply Voltage | 230 VAC |
| Response Time | 20 ms |
| Operating Temperature | 10 to 60 Deg C |
| Zero Point Stability | 0.5 % FS / year |
| Protection Class | IP 65 |
Special features:
Additional Information:
View Complete details
Product Brochure
| Pressure Range | +-25, 1000 PA |
| Operating Range | +-25, +-50, +-100, +-500, 25, 50, 250, 1000 PA |
| Output Signal | 4-20 mA |
| Usage/Application | Clean Room |
| Measurement Type | Differential Pressure |
| Accuracy | 0.4 % +-0.4 Pa |
| Working And Storage Temperature | -5...50 DegreeC |
| Model Name/Number | DPT-Priima |
| Brand | HK Instruments |
| Overload pressure max | 10 Kpa |
| Maximum Working Pressure | 30 kPa |
| Zero and Span Adjustments | Automatic autozero and manual pushbutton |
| Voltage | 0..10V |
| Supply voltage (AC / DC) | 24 V |
| Storage Temperature and Moisture | -40...70 DegreeC |
| Process Wetted Material | ABS |
| Power consumption: | 1.0 W 1.2 W with output current 20 mA |
| Protection standard: | IP54 |
| output signals (3-wire): | 0 10 VDC 4 20 mA |
| Operating temperature: | -20 +50 DegreeC (with autozero calibration -5 +50 DegreeC) |
| Response time: | 0.4 / 8 s |
View Complete details
Product Brochure
| Pressure Range | 0-500 bar |
| Output Signal | Foundation Fieldbus / Modbus |
| Measurement Type | Differential Pressure |
| Supply voltage (AC / DC) | 24 V |
| Process Wetted Material | SS316 |
| Accuracy | +-0.1% FS |
| Output signal: | via Modbus |
| operating temperature: | -20 +50 DegreeC (with autozero calibration -5 50 DegreeC) |
| Protection standard: | IP54 |
| Supply voltage: | 24 VAC 10 24 VDC 10 |
| Power consumption: | 1.0 W |
Multifunctional differential pressure transmitters with air flow measurement and Modbus communication
DPT-MOD is a multifunctional transmitter for measuring volume flow, velocity, and static and differential pressure. The measurements can be read and the configuration done via Modbus communication. DPT-MOD requires less wiring than the traditional 3-wire transmitters because multiple devices can be connected on serial line. DPT-MOD can also be used with several different measurement probes such as FloXact™ or pitot tube, and air dampers.
DPT-MOD series devices include:
• Two selectable functions:
o Measure and monitor in-duct volume flow, velocity or
differential pressure
o Measure and monitor air flow across centrifugal fans
• Multiple selectable measurement units:
o Volume flow: m3/s, m3/h, cfm, l/s
o Velocity: m/s, ft/min
o Pressure: Pa, inWC, mmWC, kPa, mbar
• Modbus communication protocol
DPT-MOD series device options offer:
• AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy
View Complete details
Product Brochure
| Pressure Range | 0-500 bar |
| Output Signal | 4-20 mA |
| Measurement Type | Differential Pressure |
| Model Name/Number | P 29 |
| Brand | Halstrup-Walcher |
| Storage Temperature and Moisture | 10 .. 70 Degree C |
| Process Wetted Material | SS316 |
| Product Weight | approx. 750 g |
| Accuracy | +-0.5% FS |
Special features
View Complete details
Product Brochure
| Pressure Range | 0...6 bar |
| Operating Range | up to 6 bar |
| Usage/Application | Air-conditioning, heating and water systems |
| Output Type | Analog: 4 ... 20 mA, 2-wire or 0 ... 10 V, 3-wire |
| Model Name/Number | DPTL |
| Brand | HK Instruments Oy |
| Accuracy | +-1 % FS |
| Protection Type | IP65 |
| Rated Supply Voltage | 24 VDC / VAC (+-20 %) |
| Response Time | 10 ms |
The DPTL is made for differential pressure detection in liquids for air-conditioning, heating and water systems. The equipment can withstand mildly corrosive substances and liquids.
Applications
PTL and DPTL series pressure transmitters are suitable for measuring pressure in neutral fluids and non-aggressive gases. Also compatible with refrigerants. They are suitable for all kind of tasks in air-conditioning, heating and water systems.
Additional Information:
View Complete details
| Use | Gas |
| Pressure Type | Gauge Pressure |
| Pressure Range (Upto) | 2000 Bar |
| Model Name/Number | Differential Pressure Gauge 990 |
| Accuracy Class | 0.1 |
| Pointer Material | Aluminium Black |
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
| Model Name/Number | DPT-R8 |
| Brand | HK Instruments Oy |
| Accuracy | 1% (from applied pressure) |
| Rated Supply Voltage | 24 VAC or VDC, +-10 % |
| Response Time | 0.8 / 8 s |
| Output Type | Analog: (0 To 10 V or 4 To 20 mA, selectable) |
| Operating Temperature | -20 To + 50 Deg. C |
| Protection Standard | IP54 |
| Burst Pressure | 30 kPa |
Measuring ranges:
Additional Information:
View Complete details
Product Brochure
| Model Name/Number | DPT-Priima |
| Brand | HK Instruments Oy |
| Accuracy | 0.4 % + +-0.4 Pa |
| Response Time | 0.4 / 8 s |
| Measuring Ranges | -25 to +25 / -50 to +50 / -100 to +100 / -500 to +500 / 0 to 25 / 0 to 50 / 0 to 250 / 0 to 1000 Pa |
| Zero Point Calibration | Automatic with autozero element (-AZ) or by pushbutton |
| Supply Voltage | 24 VDC +-10 % / 24 VAC +-10 % |
| Power Consumption | Less Than 1.0 W (< 1.2 W with output current 20 mA) |
| 3 Wire Output Signals | 0 to 10 VDC , 4 to 20 mA |
| Operating Temperature: | -20 to +50 DegreeC (with autozero calibration -5 to +50 DegreeC) |
| Protection Standard | IP54 |
DPT-Priima is a high accuracy differential pressure transmitter designed for cleanrooms and other high accuracy applications. DPT-Priima has a new, extremely accurate sensor, optional span point calibration and automatic zero point calibration.
View Complete details
Product Brochure
| Output Signal | 4-20 mA |
| Usage/Application | air, all non-aggressive gases application |
| Measurement Type | Differential Pressure |
| Accuracy | +- 0.2% FS and +- 0.5% or +- 1% FS |
| Model Name/Number | PIZ |
| Working And Storage Temperature | - 10 to 70 Degree C |
| Brand | Halstrup-Walcher GmbH |
| Supply voltage (AC / DC) | 24 V |
| Overload pressure max | 10 x for measurement ranges |
| Temperature Range | -20DegC to +70DegC |
| Rated Supply Voltage | 10-32 VDC (two-wire system) |
| Process Wetted Material | SS316 |
| Measurement Ranges | 50 / 100 / 250 / 500 Pa 1 / 2.5 / 5 / 10 / 20 / 50 / 100 kPa (others available on request) |
| Sensor response time | 20 ms |
| Protection class | IP 65 |
| Operating Temperature | 10 to 60 Degree C |
Special features:
Additional Information:
View Complete details
Product Brochure
| Output Signal | Foundation Fieldbus / Modbus |
| Measurement Type | Differential Pressure |
| Supply Voltage | 24 V |
| Process Wetted Material | SS316 |
| Accuracy | +-0.1% FS |
| Country of Origin | Made in India |
| Communication | RS-485 Modbus (RTU) |
| Output signal: | via Modbus |
| Response time: | 1 20 s selectable via menu |
| Protection standard: | IP54 |
View Complete details
Product Brochure
| Model Name/Number | DPT-Dual |
| Brand | HK Instruments Oy |
| Operating Temperature | - 20 to + 50 Deg C |
| Storage Temperature | - 40 to + 70 Deg C |
| Humidity | 0 to 95 % rH, non condensing |
| Dimensions | 102.0 x 71.5 x 36.0 mm |
| Weight | 150 g, with accessories 290 g |
| Mounting | 2 each 4.3 mm screw holes, one slotted |
| Protection Standard | IP54 |
| Voltage Output | 2x5/10V (selectable via jumper) |
| Voltage Input | 24 VAC or VDC, +-10 % |
DPT-Dual series devices include:
View Complete details
Minimum Order Quantity: 01 Piece
Product Brochure
| Model Name/Number | DPT-Ctrl |
| Brand | HK Instruments Oy |
| Operating Temperature | -20 to 50 Deg C |
| Storage Temperature | -40 to 70 Deg C |
| Humidity | 0 to 95 % rH,non condensing |
| Dimensions | 90.0 x 95.0 x 36.0 mm |
| Weight | 150 g |
| Mounting | 2 each 4.3 mm screw holes,one slotted |
| Protection Standard | IP54 |
| Proof Pressure | 25 kPa |
| Burst Pressure | 30 kPa |
DPT-Ctrl series devices include:
Multiple field selectable measurement units:
Unique proportional output options:
DPT-Ctrl series device options offer:
Additional Information:
View Complete details