Call 08048971769 78% Response Rate

Send Enquiry

our range

Air Flow And Velocity Transmitters

These Air Flow And Velocity Transmitters are unique devices that make measuring air flow and air velocity easier than ever before. Together with FLOXACT™ measurement probes the same devices are the right option when measuring flow in a duct. Again, if you wish to measure air velocity, your selection would be AVT which offers multiple measuring ranges in a single device together with relay and temperature output signals.

Stack Air Velocity Transmitter

  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
  • Stack Air Velocity Transmitter
Stack Air Velocity Transmitter
Get Best Quote
Rs 56,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeLED, 4 Digit
Hook TypeRound
Accuracy1%
Range0-10, 20, 30, 40, 60 m/sec.
Model Name/Number985V
BrandBeck GmbH
Mounting TypeField mounting - wall surface
Power24 VAC/VDC
Usage/ApplicationStack air velocity measurement
Stack Air Velocity Transmitter with S -Type Pitot Tube


The easiest way to determine Flow Velocity is to measure the Velocity Pressure in the duct with a S -type Pitot Tube Assembly connected to a differential pressure transmitter cum air velocity transmitter.

The S - type pitot Assembly includes a Static Pressure Probe and a Total Pressure Probe. A Total Pressure Probe, aligned into the airflow, senses the duct velocity pressure and the static pressure, which equals the total pressure. A Static Pressure Probe aligned at a right angle to the airflow senses only the static pressure. The difference between the total pressure reading and the static pressure reading is the Velocity Pressure. If you connect the Total Pressure Probe to the HIGH port on a differential pressure sensor and the Static Pressure Probe to the LOW port on the differential pressure sensor, then the sensor’s output will be the Velocity Pressure, as shown in the figures below.


To calculate Air Flow in Cubic Feet per Minute (CFM), determine the Flow Velocity in feet per minute, then multiply this figure by the Duct Cross Sectional Area. Air Flow in CFM (Q) = Flow Velocity in Feet per Minute (V) x Duct Cross Sectional Area (A)

Additional Information:

  • Delivery Time: Ready stock

View Complete details

Yes! I am Interested Request a call back

DPT-Ctrl-MOD Differential Pressure & flow Controller

  • DPT-Ctrl-MOD  Differential Pressure & flow Controller
  • DPT-Ctrl-MOD  Differential Pressure & flow Controller
  • DPT-Ctrl-MOD  Differential Pressure & flow Controller
  • DPT-Ctrl-MOD  Differential Pressure & flow Controller
  • DPT-Ctrl-MOD  Differential Pressure & flow Controller
DPT-Ctrl-MOD  Differential Pressure & flow Controller
Get Best Quote
Rs 15,200  / PiecePrice on Request

Product Brochure

Measuring Range-25000...2500 Pa to -70000...7000 Pa
Operating Range-250....2500 Pa
Accuracy125 Pa = 1 % + +-2 Pa
Zero and Span AdjustmentsManual pushbutton or Modbus
Maximum Working Pressure25 kPa
Supply voltage (AC / DC)24 V
Overload pressure max30 kPa
Process Wetted MaterialABS
Country of OriginMade in India

DPT-Ctrl-MOD enables to control constant pressure or flow of fans, VAV systems or dampers. In addition, the controller is fully programmable via Modbus.
The DPT-Ctrl-MOD includes an Input terminal that enables the reading of multiple signals such as temperature or control relays over Modbus. The Input terminal has one input channel designed to accept 0−10 V, NTC10k, Pt1000, Ni1000/(-LG), and BIN IN (potential free contact) signals.

View Complete details

Yes! I am Interested Request a call back

Portable Air Velocity Meter

  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
  • Portable Air Velocity Meter
Portable Air Velocity Meter
Get Best Quote
Rs 63,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeLCD
Accuracy+ - 0.5%of max. value
Model Name/NumberEMA200
BrandHalstrup-Walcher GmbH
Power9 V battery
Usage/ApplicationStack air velocity measurement
A reliable and accurate portable instrument for measuring pressure and differential pressure and air velocity. (with pitot tube).


Features:
  • High-end pressure gauge for differential pressure and flow measurements
  • Adjustable pitot factor and density
  • Zero-point correction at the push of a button
  • Min./max. value memory
  • Temperature measurement

Measurement range 
  1. ±200 Pa (±2 mbar) 1.5..18 m/s 
  2. ±2 kPa (±20 mbar) 5..58 m/s 
  3. ±20 kPa (±200 mbar) 15..180 m/ s 
  4. ± 200 kPa (±2000 mbar) 

View Complete details

Yes! I am Interested Request a call back

Air Velocity Transmitter AVT

  • Air Velocity Transmitter AVT
  • Air Velocity Transmitter AVT
  • Air Velocity Transmitter AVT
  • Air Velocity Transmitter AVT
  • Air Velocity Transmitter AVT
  • Air Velocity Transmitter AVT
Air Velocity Transmitter AVT
Get Best Quote
Rs 12,500  / PiecePrice on Request

Product Brochure

Measured mediaAir
Measuring Range0…2 m/s, 0…10 m/s, 0…20 m/s
Output type4-20 mA
Display TypeDigital
Usage/ApplicationAir Velocity
Hook TypeStainless Steel
BrandHK Instruments Oy
Humidity0 to 95 % rH,non-condensing
Mounting TypeMounting flange,4.0 mm
Weight220 g
Operating Temperature0 to 50 Deg C
Storage Temperature-20 to 70 Deg C
Dimensions90.0 x 95.0 x 36.0 mm
Protection StandardIP54
The AVT is an electronic air velocity and temperature transmitter for air and non-combustible gases with optional relay output. AVT series air velocity transmitters are engineered for building automation in the HVAC/R industry. The AVT measures air velocity and temperature, with  eld selectable range and output options in a single device. Designed with a duct mount probe and adjustable collar suitable for round or rectangular ducts.


AVT series devices include:

  • 3 field selectable measurement ranges for air velocity, selectable via jumper.
  • Separate readings and outputs for air velocity and temperature.
  • Proportional output options include: voltage (0–10 V) and current (4–20 mA).


AVT series device options offer:

  • Backlit display
  • Field adjustable relay

Applications:
AVT series devices are commonly used in HVAC/R systems for:
  • In-duct air flow and velocity monitoring
  • In-duct temperature monitoring
  • VAV applications

View Complete details

Yes! I am Interested Request a call back

Air Flow And Velocity Transmitter 985V

  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
  • Air Flow And Velocity Transmitter 985V
Air Flow And Velocity Transmitter 985V
Get Best Quote
Rs 29,500  / PiecePrice on Request

Minimum Order Quantity: 01 Piece

Product Brochure

Display TypeRed; 4 digits,LED
Accuracy+-0.5% FS,min. +-1 Pa
BrandBeck GmbH
Model Name/Number985V
Range0 to 100 mbar
Process Temperature-20 ... 70 Degree C
Usage/ApplicationMeasure Volume Flow Or Flow Velocity And Pressure
Analog Output0 ...10 Volt and 4 ... 20 mA
Process ConnectionHose connection with 4 / 6 mm outer diameter
Protection ClassIP65 acc. to EN 60529
Output Signal0 - 10V or 4 - 20 mA,3-wire
Supply Voltage18 to 30 VAC / VDC
Electrical ConnectionPlug-In Terminals For Wires And Strands Up To 1.5 Mm2 Or Circular Connectors M12 / 4-Pole
The transmitters of the 985V series are used to measure volume flow or flow velocity and pressure. A jumper enables switching between volume flow or flow velocity and pressure measurement.

Application:
  • HVAC systems
  • Velocity meansurement in duct
  • ID / FD Fan - Flow measurement 

  • Setting ranges:
    Depending on type between 0 to 100 mbar
  • Temperature range:
    Working and storage temperature from -20°C to +70°C
  • Process connection:
    Hose connection with 4 / 6 mm outer diameter
  • Supply voltage:
    18 to 30 VAC / VDC
  • Output signal(3-wire):
    0 - 10 V
    4 - 20 mA
  • Electrical connection:
    Plug-in terminals for wires and strands up to 1.5 mm2 or
    circular connectors M12 / 4-pole
  • Protection class:
    IP65 acc. to EN 60529


Additional Information:

  • Item Code: 985V
  • Delivery Time: Ready stock
  • Packaging Details: Box Packing

View Complete details

Yes! I am Interested Request a call back

Air Flow And Velocity Transmitter DPT-Flow

  • Air Flow And Velocity Transmitter DPT-Flow
  • Air Flow And Velocity Transmitter DPT-Flow
  • Air Flow And Velocity Transmitter DPT-Flow
  • Air Flow And Velocity Transmitter DPT-Flow
Air Flow And Velocity Transmitter DPT-Flow
Get Best Quote
Rs 12,630  / PiecePrice on Request

Product Brochure

Output Signal4–20 mA
Fluid TypeAir
Line SizeAir Application
BrandHK Instruments
Usage/ApplicationIndustrial
Model Name/NumberDPT-Flow
Hook TypeWall
Display TypeDigital
CommunicationModbus
Operating Temperature-20 to 50 Deg C
Storage Temperature-40 to 70 Deg C
Weight150 g
Mounting2 each 4.3 mm screw holes, one slotted
Humidity0 to 95 % rH, non condensing
Protection StandardIP54
Dimensions90.0 x 95.0 x 36.0 mm
DPT-Flow is a flow transmitter that provides a new and easy way to measure the flow rate on centrifugal fans.One device is suitable for a range of different fan types. It also provides an easy way to measure flow rate in a duct system. The device is supplied with an optional FloXactTM averaging measurement probe.


Usage:

The DPT-Flow is designed for air handling units to measure the air flow on centrifugal fans. The DPT-Flow can be used as an on-site display for flow or as a transmitter to regulate the air flow on a selected fan or blower. The DPT-Flow can also be used in the duct system or in air handling units as an on-site display for flow or as a transmitter to regulate the air flow in a duct. The device can be used with several different measurement probes such as FloXactTM or pitot tube, and air dampers. The requirement is that the K-value of the measurement probe or damper is known.


DPT-Flow series devices include:

  • Two field selectable functions:
  • Measure and monitor in-duct volume flow, velocity or differential pressure
  • Measure and monitor air flow across centrifugal fans


Multiple field selectable measurement units:

  • Volume flow: m3/s, m3/h, cfm, l/s
  • Velocity: m/s, ft/min
  • Pressure: Pa, inWC, mmWC, kPa, mbar, psi

 

Unique proportional output options:

  • Volume flow or velocity: voltage (0–10 V) or current (4–20 mA)
  • Pressure: voltage (0–10 V) or current (4–20 mA)



DPT-Flow series device options offer:

  • AZ (autozero) function for automatic zero point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy

Applications:
AVT series devices are commonly used in HVAC/R systems for:
  • Air flow monitoring across centrifugal fans and blowers
  • In-duct temperature monitoring
  • VAV applications

View Complete details

Yes! I am Interested Request a call back

Floxact Multiple Sensing points Averaging Pitot Tube

  • Floxact Multiple Sensing points Averaging Pitot Tube
  • Floxact Multiple Sensing points Averaging Pitot Tube
  • Floxact Multiple Sensing points Averaging Pitot Tube
  • Floxact Multiple Sensing points Averaging Pitot Tube
  • Floxact Multiple Sensing points Averaging Pitot Tube
Floxact Multiple Sensing points Averaging Pitot Tube
Get Best Quote
Rs 7,500  / PiecePrice on Request

Product Brochure

Tube MaterialSS304
Model Name/NumberFloxact - R150
MaterialAluminium
BrandHK Instruments Oy
Size100, 125, 160, 200, 250, 315, 400, 450...1200 mm
ApplicationDuct Line
Accuracy+-2.0 %
The FloXact™ probe is a differential air pressure device designed to measure air volume flow in a duct. It includes multiple sensing points to measure total and static pressures. The FloXact™ probe incorporates a unique design to amplify the differential pressure by 2.5 times for accurate measurement of lower air velocities down to 1.0 m/s (200 fpm). It is easy to install and cost-effective.

View Complete details

Yes! I am Interested Request a call back

Battery Powered Differential Pressure, DPT- FLOW-Batt

  • Battery Powered Differential Pressure, DPT- FLOW-Batt
  • Battery Powered Differential Pressure, DPT- FLOW-Batt
  • Battery Powered Differential Pressure, DPT- FLOW-Batt
Battery Powered Differential Pressure, DPT- FLOW-Batt
Get Best Quote
Rs 17,120  / PiecePrice on Request

Product Brochure

Pressure Range-70000...7000
Country of OriginMade in India
Zero point calibration:by pushbutton
Measuring units:Pressure: Pa, kPa, mbar, inchWC, mmWC, psi Flow: m3/s, m3/hr, cfm, l/s, m/s, ft/min
Current consumption:20 mA on active mode
Operating temperature:-20 +50 DegreeC

One device is suitable for a range of different fan types. It also provides an easy way to measure flow rate in a duct system for example together with a FloXactTMaveraging measurement probe.

Usage

The DPT-Flow-Batt is an on-site display designed for air handling units to measure the air flow on centrifugal fans. The DPT-Flow-Batt can also be used in the duct system as an on-site display for flow. The device can be used with several different measurement probes such as FloXactTM or pitot tube, and air dampers. The requirement is that the K-value of the measurement probe or damper is known.

Brand : HK Instruments

View Complete details

Yes! I am Interested Request a call back